-
Partially revised provisions of "Code for Fire Protection of Building Design" GB50016-2014 (2018 edition)Time of issue : 2019-05-14
Recently, the Ministry of Housing, Urban and Rural Construction issued a partial revision of the national standard "Code for Fire Protection Design of Buildings" GB50016-2014 (2018 Edition) (hereinafter referred to as "Code"). The new revised "Code" will be implemented on October 1, 2018.
Professor Zhou Yanmin of the School of Architecture, Tsinghua University, as a member of the Architectural Design Standardization Technical Committee of the Ministry of Civil Affairs and the Ministry of Housing and Urban-Rural Development, has participated in several seminars organized by the civil affairs, fire protection and housing urban-rural construction departments in the past year. After the introduction of the revised provisions, Zhou Yanmin's studio conducted a study on the contents of the "Standards", and combined with the previous research results, made a graphic interpretation of the main revised provisions.
1 The scope of application of the revised provisions in facilities for the elderly
What kind of "elderly facilities" need to be designed according to the new "Code"?
The scope of application of the revised provisions of "Code for Fire Protection of Architectural Design"
The total number of beds (to accommodate the elderly) is greater than or equal to 20 beds (persons), public buildings that provide centralized care services for the elderly, including elderly full-day care facilities and elderly day care facilities. Other non-centralized care facilities or places exclusively for the elderly, such as elderly universities, elderly activity centers, etc., are not included in the elderly care facilities.
2 Matters needing attention when constructing elderly care facilities independently or jointly
2.1 The new "standard" high-rise elderly care facilities are classified as a high-rise civil building
Article 5.1.1 of the new Code: The independently built elderly care facility with a building height greater than 24m is a type of high-rise civil building.
The old building in the original "Code" with a building height greater than 50m is a type of high-rise civil building. The standards in the new "Code" have been improved, and the elderly care facilities that are independently constructed (including adjacent construction) above 24m are a type of high-rise civil buildings.
2.2 Selection of construction location for elderly care facilities
Article 5.4.4A of the new Code: The elderly care facilities should be set up independently. When the elderly care facility is combined with other buildings up and down, the elderly care facility should be set in the lower part of the building and should meet the following requirements:
1. The number of building floors, building heights or the height of the floor location of the elderly care facility part shall comply with the provisions of Article 5.3.1A of this code;
2. Part of the elderly care facilities should be separated from other places by fire protection, and the fire separation should comply with the provisions of Article 6.2.2 of this code.
The new "Code" puts forward clear requirements for the location of elderly care facilities (independent, preferably in the lower part), and its height (not more than 32m, not more than 54m) and fire separation (floor fire resistance limit 1.0h, separation The wall fire resistance 2.0h) is specified. It is pointed out in the article description that, for some of the remodeled buildings, when it is restricted by the upper and lower use functions and floor layout in the building, try to set up independent entrances and exits.
2.3 Exterior wall materials for elderly care facilities
New "Code" Article 6.7.4A: In addition to the circumstances specified in Article 6.7.3 of this code, the following inner and outer wall and roof insulation materials for elderly care facilities shall use insulation materials with Class A burning performance:
1 Independently built elderly care facilities;
2 The elderly care facility constructed in combination with other buildings and the total construction area of the elderly care facility part is greater than 500㎡.
The new "Code" sets clear fire protection requirements for the raw materials of exterior walls and roof insulation materials of elderly care facilities. Special attention should be paid to the use of combustion performance A for external walls and roofs when the elderly care facilities are more than 500m2 with other buildings. Grade insulation material.
3 Height of care facilities for the elderly
3.1 54m-height limit
5.3.1A The building height of the independently constructed first- and second-grade fire-resistant senior care facilities should not be greater than 32m, and should not be greater than 54m; the independently-built third-grade fire-resistant senior care facilities should not exceed 2 floors.
The original "Code" does not put restrictions on the height of the elderly care facilities. The new "Code" clearly states that it should not exceed 54m. And it is clearly stated -
Seismic code "Code for seismic design of buildings" (2016 edition)Time of issue : 2019-05-14
Announcement of the Ministry of Housing, Urban and Rural Construction on the partial revision of the national standard "Code for Seismic Design of Buildings"
Now approves the partially revised provisions of the "Code for Seismic Design of Buildings" GB50011-2010, effective August 1, 2016 The conditions of the original text after this revision are also abolished.
Partially revised articles and specific contents will be published on our website and the recently published "Engineering and Construction Standardization" publication.
Ministry of Housing, Urban and Rural Construction
July 7, 2016
The specific "Code for Seismic Design of Buildings" GB50011-2010 is partially revised as follows. Note: The underline in the lower text indicates the modified content; the provisions in bold are mandatory provisions and must be strictly implemented.
Revision Instructions
This partial revision is based on the requirements of the “Notice on Printing and Distributing the Revision Plan for 2014 Engineering Construction Standards and Regulations” (Jianbiao [2013] No. 169) issued by the Ministry of Housing and Urban-Rural Development. , Research and teaching units partially revised the "Code for Seismic Design of Buildings" GB 50011-2010.
The main contents of this partial revision include two aspects:
1 According to "China Earthquake Parameter Zoning Map" GB18306-2015 and "People's Republic of China Administrative Division 2015" and the Ministry of Civil Affairs issued the 2015 administrative division change communiqué, amend "Building Seismic Design Code" GB50011-2010 Appendix A Urban seismic fortification intensity, design basic earthquake acceleration, and design earthquake grouping ".
2 In accordance with the "Codes for Seismic Design of Buildings" GB50011-2010 since the implementation of the feedback and suggestions from all parties, some provisions have been adjusted in writing. During the revision process, opinions from various parties were extensively consulted, and the specific revisions were repeatedly discussed and revised, coordinated with relevant standards, and finally finalized after review.
This partial revision involves a modification of an appendix and 10 articles, namely Appendix A and Article 3.4.3, Article 3.4.4, Article 4.4.1, Article 6.4.5, Article 7.1.7 , Article 8.2.7, Article 8.2.8, Article 9.2.16, Article 14.3.1, Article 14.3.2.
The underlined part of the provisions of this specification is the modified content; the provisions in bold are mandatory provisions and must be strictly implemented.
Editor for this partial revision: China Academy of Building Research
Participants in this partial revision: Institute of Geophysics, China Earthquake Administration, China Institute of Architectural Standards and Design, Beijing Institute of Architectural Design, China Electronics Engineering Design Institute
Main drafters: Huang Shimin, Wang Yayong, Dai Guoying, Fu Shengcong, Luo Kaihai, Li Xiaojun, Ke Changhua, Yu Yinquan, Lou Yu, Xue Huili
Main reviewers: Xu Peifu, Qi Wuhui, Fan Zhong, Wu Jian, Guo Mingtian, Wu Hanfu, Ma Donghui, Song Bo, Pan Peng
XINSHUO
Scan it
More information
Add:Middle Section of Taoyuan Avenue, Plain Economic Development Zone, Dezhou City, Shandong Province
Tel:+86-534-8936003
E-Mail:dzxs@jiangshankeji.com
Website:www.jiangshankeji.cn
Copyright © 2020 Xinshuo New Building Materials All rights reserved 鲁ICP备13019751号-1